Tank Top Return-Line Filters

Pi 500 Nominal Size 40 up to 100

Pi 500 Nominal Size 40 up to 100

Technical Data

Design
Tank top mounted filter, threaded or flanged
Nominal pressure
10 bar
Flow rate
Up to 100 l/min
Temperature range
-10°C to +80°C
(other temperature ranges on request)
Bypass setting
Δρ 3.5 bar ±10%
Material
 
Filter head
Gadolinium aluminium
Filter bowl
Plastic
Filter cover
Plastic
Indicator / switch setting
Δρ 2.2 bar ±10%
 
Electrical specifications of pressure indicator
 
 
 
Current load
1 A
Contact load
70 W
Voltage
230 V AC
Type of protection
IP 65
Contact
Normally open / normally closed
 

The electrical indicator function can be changed from the Normally Open position to the Normally Closed position or vice versa by inverting the electrical section.

Inductivity in the direct current may require the use of a signal suppressor.

For further information please see our Contamination Indicators

Recommended max flow rate at 500 cSt using a 3 µm element:

  • NG 40 8l/min
  • NG 63 15l/min
  • NG 100 25l/min

Features

  • Modular and compact design
  • Minimal pressure drop
  • Visual / electrical contamination control
  • Highly efficient Mic or PS filter elements
  • Beta-rated elements per ISO 4572
  • Large dirt-holding capacity and high differential pressure stability providing optimum element service life

Pi 500 Nominal Size 160 up to 1000

Pi 500 Nominal Size 160 up to 1000

Technical Data

Design
Tank top mounted filter, threaded or flanged
Nominal pressure
10 bar
Flow rate
Up to 1000 l/min
Temperature range
-10°C to +120°C
(other temperature ranges on request)
Bypass setting
Δρ 3.5 bar ±10%
Material
 
Filter head
Gadolinium aluminium
Filter bowl
Steel
Filter cover
Gadolinium aluminium
Indicator / switch setting
Δρ 2.2 bar ±10%
 
Electrical specifications of pressure indicator
 
 
 
Current load
1 A
Contact load
70 W
Voltage
230 V AC
Type of protection
IP 65
Contact
Normally open / normally closed
 

The electrical indicator function can be changed from the Normally Open position to the Normally Closed position or vice versa by inverting the electrical section.

Inductivity in the direct current may require the use of a signal suppressor.

For further information please see our Contamination Indicators

Filters compatible with standard mineral oils.

Please contact us when other fluids apply.

Recommended max flow rate at 500 cSt using a 3 µm element:

Features

  • Modular and compact design
  • Minimal pressure drop
  • Visual / electrical contamination control
  • Highly efficient Mic or PS filter elements
  • Beta-rated elements per ISO 4572
  • Large dirt-holding capacity and high differential pressure stability providing optimum element service life