Medium Pressure Filters
Pi 340
Pi 340
Technical Data
- Design
- In-line filter, flanged, SAE
- Operating pressure
- 250 bar
- Static test pressure
- 325 bar
- Flow rate
- Up to 450 Liters /min
- Temperature range
- -10°C to +120°C
- (other temperature ranges on request)
- Bypass setting
- Δ ρ 7 bar ±10%
- Material
- Filter head
- Ductile cast iron
- Filter bowl
- Hardened steel
- Seal
- NBR
- PTFE
- Copper
- Indicator setting
- Δ ρ 5 bar ± 10%
- Electrical specifications of pressure indicator
- Current load
- 1 A
- Contact load
- 70 W
- Voltage
- 230 V AC
- Type of protection
- IP 65
- Contact
- Normally open / normally closed
The electrical indicator function can be changed from the Normally Open position to the Normally Closed position or vice versa by inverting the electrical section.
Inductivity in the direct current may require the use of a signal eraser.
For further information please see our Contamination Indicators
Features
- Modular and compact design
- Minimal pressure drop
- Visual / electrical contamination control
- Highly efficient PS filter elements
- Beta-rated elements per ISO 4572
- Large dirt-holding capacity and high differential pressure stability providing optimum element service life
Pi 360
Pi 360
Technical Data
- Design
- In-line filter, threaded, BSP ports
- Operating pressure
- 210 / 350 bar
- Flow rate
- Up to 450 Liters /min
- Temperature range
- -10°C to +120°C
- (other temperature ranges on request)
- Bypass setting
- Δρ 7 bar
- Material
- Filter head
- Ductile cast iron
- Filter bowl
- Hardened steel
- Seal
- NBR
- PTFE
- Copper
- Indicator setting
- Δρ 5 bar ±10%
- Electrical specifications of pressure indicator
- Current load
- 1 A
- Contact load
- 70 W
- Voltage
- 230 V AC
- Type of protection
- IP 65
- Contact
- Normally open / normally closed
Features
- Modular and compact design
- Minimal pressure drop
- Visual / electrical contamination control
- Highly efficient PS filter elements
- Beta-rated elements per ISO 4572