level meters
Bypass
Bypass
Connection: Screwed or flanged
Technical Data
- Connection
- Screwed or flanged
- A.W.P
- 316 SS (PTFE lined or borosilicate glass optional)
- PVDF
- PP
- PVC
- Length
- 150mm to 6000mm
- Level indication
- local or remote
- Output
- 4 mA to 20 mA, Hart, reed or proximity sensor contact
- Operating pressure
- up to 40 MPa
- Operating temperature
- -160°C up to 450°C
- EX-version
- EEx ia II C T1 - T6
Capacitance
Capacitance
Connection: Screwed
Technical Data
- Connection
- Screwed
- Size
- ¾ inch BSP
- Material
- 316 SS
- Length
- 200mm to 3000mm
- Supply
- 14 V DC to 30 V DC
- 2-wire connection
- Output analogue
- 4 mA to 20 mA
- 2-wire connection
- Output digital
- 2x potential free NPN
- Sensor
- PTFE coated aluminium tube
Displacement
Displacement
Connection: Screwed or flanged
Technical Data
- Connection
- Screwed or flanged
- Size
- ½ inch to 4 inch
- (special on request)
- Guide tube Material
- 316 SS
- PVC
- PP
- PVDF
- (Ti, Hastelloy B or C on request)
- Float material
- 316 SS
- PVC
- PP
- PVDF
- Length
- 100mm to 6000mm
- Suppply
- 18 V DC to 30 V DC
- 2-wire connection
- Output
- 4 mA to 20 mA
- 2-wire connection, Hart
Hydrostatic
Hydrostatic
Technical Data
- Length
- 1m (100 mbar) to 100m (10 bar)
- Suppply
- 14 V DC to 30 V DC
- 2-wire connection
- Output analogue
- 4 mA to 20 mA
- 2-wire connection
- Sensor material
- 316 SS
- Option
- EX-version available
Float Type with Local Display
Float Type with Local Display
Connection: Screwed
Technical Data
- Connection
- Screwed
- Size
- 1 inch, 1½ inch and 2 inch BSP
- Material
- 316 SS
- Length
- 250mm, 500mm, 750mm, 1000mm, 1500mm and 2000mm
- Suppply
- 10 V DC to 30 V DC
- 3-wire connection
- Output
- 4 mA to 20 mA
- Display
- OMNI local LCD with programming ring